AC input voltage range |
100~305VAC 142~431VDC(please refer to "STATIC CHARACTERISTIC"section) |
AC inrush current |
cold start 50A(twidth=500μs,measured at 50% Ipeak) at 230VAC;Per NEMA 410 |
Over current protection |
95~108% Hiccup mode or Constant current limiting ,recovers automatically after fault condition is removed |
Over voltage protection |
12V:13.5~18V, 24V:27~34V Shut down output voltage,re-power on to recover |
Short circuit protection |
Hiccup mode, recovers automatically after fault condition is removed |
Over temperature protection |
Shut down output voltage ,recovers automatically after fault condition is removed |
Input over voltage protection |
320~390VAC(Shut down output voltage when the input voltage exceeds protection voltage) can survive input voltage stress of 440Vac for 48 hours |
Setup, rise, hold up time |
500ms,100ms/230VAC 1200ms,100ms/115VAC;10ms/115VAC,230VAC |
Withstand voltage |
I/P-O/P:4.2KVAC I/P-FG:2.1KVAC O/P-FG:1.5KVAC |
Working temperature |
Tcase=-40~+90℃(Please refer to "OUTPUT LOAD vs TEMPERATURE" section) |
Safety standards |
UL8750(type "HL"),UL879,CSA C22.2 No.250.13-12;ENEC EN61347-1 ,EN61347-2-13 independent,EN62384; GB19510.1,GB19510.14;EAC TP TC 004;IP67 approved |
EMC standards |
EN55015(CISPR15);EN61000-3-2,3;EN61000-4-2,3,4,5,6,8,11 |
Dimension (LxWxH) |
180x63x35.5mm |
Packing |
0.8Kg,16pcs/13.4Kg/0.67CUFT |